Designed in 2017 in accordance with European market demand. TD 600 model is designed on the base of TD 500. Featuring RS-232 interface.
SPECIFICATIONS:
• Measured medium Gazoline, diesel
• Digital output resolution 0,1%
• Analog output resolution 0,25%
• Analog output range 0,2 - 9 V
• Frequency output range 300 - 4395 Hz
• Impulse output range 2 - 1025 impulses
• Measuring error, maximum 1%
• Nonlinearity value, maximum 1%
• Power supply voltage 7 - 80 V (starting from serial number 10776)
• Power supply current, maximum 30 mA
• Ingress protection IP67
• Operational temperature range -60... +85 С о